Gas Discharge Tube Arresters (GDT) are circuit protection components used to protect electronic systems from high-energy surge events, lightning-induced transients and overvoltage conditions. They are widely used in communication equipment, power supplies, industrial control systems, telecom lines, networking devices, security systems, renewable energy equipment, meters and building electrical protection.
This category includes gas discharge tubes, GDT surge arresters, two-electrode GDTs, three-electrode GDTs, lightning protection arresters and related overvoltage protection components. These devices are commonly selected based on DC spark-over voltage, impulse discharge current, insulation resistance, capacitance, response characteristics, package type, safety standards and application requirements.
TomatoElec supplies original Gas Discharge Tube Arresters from recognized manufacturers such as Bourns, Littelfuse, TDK, EPCOS, Vishay, Eaton, Bel Fuse, Murata, Panasonic and other major brands. As an in-stock electronic components supplier and independent distributor, TomatoElec provides inventory support, original component sourcing and BOM sourcing services for global customers.
| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Package/Case | Series | Packaging | Product Status | Voltage - DC Spark Over (Nom) | Impulse Discharge Current (8/20µs) | Tolerance | Number of Poles | Fail Short | Mounting Type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
2036-35-C2FLFGDT 350V 10KA 3 POLE TH |
9,852 | - |
|
Datasheet |
Axial Cylinder, 3 Lead (Radial Bend) | Mini-TRIGARD™ 2036 | Bulk | Obsolete | 350 V | 10000A (10kA) | ±20% | 3 | Yes | Through Hole |
|
|
2036-40-C2LFGDT 400V 10KA 3 POLE TH |
5,459 | - |
|
Datasheet |
Axial Cylinder, 3 Lead (Radial Bend) | Mini-TRIGARD™ 2036 | Bulk | Obsolete | 400 V | 10000A (10kA) | ±20% | 3 | No | Through Hole |
|
|
2036-40-C3LFGDT 400V 10KA 3 POLE TH |
3,737 | - |
|
Datasheet |
Axial Cylinder, 3 Lead (Radial Bend) | Mini-TRIGARD™ 2036 | Bulk | Obsolete | 400 V | 10000A (10kA) | ±20% | 3 | No | Through Hole |
|
|
2036-42-C2FGDT 420V 10KA 3 POLE TH |
8,311 | - |
|
Datasheet |
Axial Cylinder, 3 Lead (Radial Bend) | Mini-TRIGARD™ 2036 | Bulk | Obsolete | 420 V | 10000A (10kA) | ±20% | 3 | Yes | Through Hole |
|
|
2036-42-C2LFGDT 420V 10KA 3 POLE TH |
4,344 | - |
|
Datasheet |
Axial Cylinder, 3 Lead (Radial Bend) | Mini-TRIGARD™ 2036 | Bulk | Obsolete | 420 V | 10000A (10kA) | ±20% | 3 | No | Through Hole |
|
|
2036-47-C2LFGDT 470V 10KA 3 POLE TH |
2,787 | - |
|
Datasheet |
Axial Cylinder, 3 Lead (Radial Bend) | Mini-TRIGARD™ 2036 | Bulk | Obsolete | 470 V | 10000A (10kA) | ±20% | 3 | No | Through Hole |
|
|
2036-47-C3LFGDT 470V 10KA 3 POLE TH |
6,905 | - |
|
Datasheet |
Axial Cylinder, 3 Lead (Radial Bend) | Mini-TRIGARD™ 2036 | Bulk | Obsolete | 470 V | 10000A (10kA) | ±20% | 3 | No | Through Hole |
|
|
2036-60-C2LFGDT 600V 10KA 3 POLE TH |
8,162 | - |
|
Datasheet |
Axial Cylinder, 3 Lead (Radial Bend) | Mini-TRIGARD™ 2036 | Bulk | Obsolete | 600 V | 10000A (10kA) | ±20% | 3 | No | Through Hole |
|
|
2036-60-C3LFGDT 600V 10KA 3 POLE TH |
2,097 | - |
|
Datasheet |
Axial Cylinder, 3 Lead (Radial Bend) | Mini-TRIGARD™ 2036 | Bulk | Obsolete | 600 V | 10000A (10kA) | ±20% | 3 | No | Through Hole |
|
|
2037-35-CLFGDT 350V 5KA 2 POLE THROUGH HOLE |
8,000 | - |
|
Datasheet |
Axial Cylinder | 2037 | Bulk | Obsolete | 350 V | 5000A (5kA) | ±15% | 2 | No | Through Hole |
|
|
2037-40-CLFGDT 400V 5KA 2 POLE THROUGH HOLE |
7,708 | - |
|
Datasheet |
Axial Cylinder | 2037 | Bulk | Obsolete | 400 V | 5000A (5kA) | ±15% | 2 | No | Through Hole |
|
|
2037-60-CLFGDT 600V 5KA 2 POLE THROUGH HOLE |
4,539 | - |
|
Datasheet |
Axial Cylinder | 2037 | Bulk | Obsolete | 600 V | 5000A (5kA) | ±15% | 2 | No | Through Hole |
|
2797971GDT 110V 10KA 2 POLE |
5,573 | - |
|
Datasheet |
- | - | Bulk | Obsolete | 110 V | 10000A (10kA) | - | 2 | No | - |
|
CG32.0L-04GDT 2000V 5KA 2 POLE TH |
4,249 | - |
|
Datasheet |
Axial Cylinder | CG3 | Tray | Active | 2000 V | 5000A (5kA) | - | 2 | - | Through Hole |
|
CG31.3L-01GDT 1300V 5KA 2 POLE TH |
2,527 | - |
|
Datasheet |
Axial Cylinder | CG3 | Tray | Active | 1300 V | 5000A (5kA) | - | 2 | No | Through Hole |
|
CG33.0L-03GDT 3000V 5KA 2 POLE TH |
5,888 | - |
|
Datasheet |
Axial Cylinder | CG3 | Tray | Active | 3000 V | 5000A (5kA) | - | 2 | No | Through Hole |
|
CG31.5L-07GDT 1500V 5KA 2 POLE TH |
3,861 | - |
|
Datasheet |
Axial Cylinder | CG3 | Tray | Active | 1500 V | 5000A (5kA) | - | 2 | No | Through Hole |
|
|
B88069X1360C103GDT 90V 20KA 2 POLE THROUGH HOLE |
7,640 | - |
|
Datasheet |
Axial Cylinder | A81 | Bulk | Discontinued at Digi-Key | 90 V | 20000A (20kA) | ±20% | 2 | No | Through Hole |
|
|
B88069X210S102GDT 2000V THROUGH HOLE |
8,618 | - |
|
- |
Axial Cylinder | SSG | Strip | Obsolete | 2000 V | - | - | - | - | Through Hole |
|
B88069X2351C102GDT 90V 5KA 2 POLE THROUGH HOLE |
2,171 | - |
|
Datasheet |