Available 24/7 at
0755-82798135Gas Discharge Tube Arresters (GDT)
Gas Discharge Tube Arresters (GDT)
Gas Discharge Tube Arresters (GDT) are circuit protection components used to protect electronic systems from high-energy surge events, lightning-induced transients and overvoltage conditions. They are widely used in communication equipment, power supplies, industrial control systems, telecom lines, networking devices, security systems, renewable energy equipment, meters and building electrical protection.
This category includes gas discharge tubes, GDT surge arresters, two-electrode GDTs, three-electrode GDTs, lightning protection arresters and related overvoltage protection components. These devices are commonly selected based on DC spark-over voltage, impulse discharge current, insulation resistance, capacitance, response characteristics, package type, safety standards and application requirements.
TomatoElec supplies original Gas Discharge Tube Arresters from recognized manufacturers such as Bourns, Littelfuse, TDK, EPCOS, Vishay, Eaton, Bel Fuse, Murata, Panasonic and other major brands. As an in-stock electronic components supplier and independent distributor, TomatoElec provides inventory support, original component sourcing and BOM sourcing services for global customers.
| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Package/Case | Series | Packaging | Product Status | Voltage - DC Spark Over (Nom) | Impulse Discharge Current (8/20µs) | Tolerance | Number of Poles | Fail Short | Mounting Type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
2026-25-C2FGDT 250V 20KA 3 POLE TH |
3,733 | - |
|
Datasheet |
Axial Cylinder, 3 Lead (Radial Bend) | TRIGARD® 2026 | Bulk | Active | 250 V | 20000A (20kA) | ±20% | 3 | Yes | Through Hole |
|
|
2026-35-C2FGDT 350V 20KA 3 POLE TH |
9,257 | - |
|
Datasheet |
Axial Cylinder, 3 Lead (Radial Bend) | TRIGARD® 2026 | Bulk | Active | 350 V | 20000A (20kA) | ±20% | 3 | Yes | Through Hole |
|
|
2026-07-C4FLFGDT 75V 20KA 3 POLE THROUGH HOLE |
9,090 | - |
|
Datasheet |
Radial Cylinder, 3 Lead | TRIGARD® 2026 | Bulk | Active | 75 V | 20000A (20kA) | ±20% | 3 | Yes | Through Hole |
|
|
2026-09-C4FLFGDT 90V 20KA 3 POLE THROUGH HOLE |
7,678 | - |
|
Datasheet |
Radial Cylinder, 3 Lead | TRIGARD® 2026 | Bulk | Active | 90 V | 20000A (20kA) | ±20% | 3 | Yes | Through Hole |
|
|
2026-20-C2FLFGDT 200V 20KA 3 POLE TH |
9,122 | - |
|
Datasheet |
Axial Cylinder, 3 Lead (Radial Bend) | TRIGARD® 2026 | Bulk | Active | 200 V | 20000A (20kA) | ±20% | 3 | Yes | Through Hole |
|
|
2026-23-A1FLFGDT 230V 20KA 3 POLE |
4,575 | - |
|
Datasheet |
Cylinder No Lead, 3 Terminal | TRIGARD® 2026 | Bulk | Active | 230 V | 20000A (20kA) | ±20% | 3 | Yes | User Defined |
|
|
2026-23-C3FLFGDT 230V 20KA 3 POLE TH |
9,508 | - |
|
Datasheet |
Axial Cylinder, 3 Lead (Radial Bend) | TRIGARD® 2026 | Bulk | Active | 230 V | 20000A (20kA) | ±20% | 3 | Yes | Through Hole |
|
|
2026-23-C4FGDT 230V 20KA 3 POLE TH |
7,817 | - |
|
Datasheet |
Radial Cylinder, 3 Lead | TRIGARD® 2026 | Bulk | Active | 230 V | 20000A (20kA) | ±20% | 3 | Yes | Through Hole |
|
|
2026-23-CFGDT 230V 20KA 3 POLE TH |
8,563 | - |
|
Datasheet |
Axial Cylinder, 3 Lead (T-Shape) | TRIGARD® 2026 | Bulk | Active | 230 V | 20000A (20kA) | ±20% | 3 | Yes | Through Hole |
|
|
2026-25-C2FLFGDT 250V 20KA 3 POLE TH |
9,364 | - |
|
Datasheet |
Axial Cylinder, 3 Lead (Radial Bend) | TRIGARD® 2026 | Bulk | Active | 250 V | 20000A (20kA) | ±20% | 3 | Yes | Through Hole |
|
|
2026-26-C2FLFGDT 260V 20KA 3 POLE TH |
3,131 | - |
|
Datasheet |
Axial Cylinder, 3 Lead (Radial Bend) | TRIGARD® 2026 | Bulk | Active | 260 V | 20000A (20kA) | ±20% | 3 | Yes | Through Hole |
|
|
2026-30-C2FLFGDT 300V 20KA 3 POLE TH |
9,562 | - |
|
Datasheet |
Axial Cylinder, 3 Lead (Radial Bend) | TRIGARD® 2026 | Bulk | Active | 300 V | 20000A (20kA) | ±20% | 3 | Yes | Through Hole |
|
|
2026-35-C4FGDT 350V 20KA 3 POLE TH |
4,420 | - |
|
Datasheet |
Radial Cylinder, 3 Lead | TRIGARD® 2026 | Bulk | Active | 350 V | 20000A (20kA) | ±20% | 3 | Yes | Through Hole |
|
|
2026-35-C4FLFGDT 350V 20KA 3 POLE TH |
7,413 | - |
|
Datasheet |
Radial Cylinder, 3 Lead | TRIGARD® 2026 | Bulk | Active | 350 V | 20000A (20kA) | ±20% | 3 | Yes | Through Hole |
|
|
2026-40-C13FGDT 400V 20KA 3 POLE TH |
5,806 | - |
|
Datasheet |
Axial Cylinder, 3 Lead (Radial Bend) | TRIGARD® 2026 | Bulk | Active | 400 V | 20000A (20kA) | ±20% | 3 | Yes | Through Hole |
|
|
2026-40-C2FLFGDT 400V 20KA 3 POLE TH |
4,791 | - |
|
Datasheet |
Axial Cylinder, 3 Lead (Radial Bend) | TRIGARD® 2026 | Bulk | Active | 400 V | 20000A (20kA) | ±20% | 3 | Yes | Through Hole |
|
|
2026-42-C4FLFGDT 420V 20KA 3 POLE TH |
4,538 | - |
|
Datasheet |
Radial Cylinder, 3 Lead | TRIGARD® 2026 | Bulk | Active | 420 V | 20000A (20kA) | ±20% | 3 | Yes | Through Hole |
|
|
2026-47-C2FGDT 470V 20KA 3 POLE TH |
6,318 | - |
|
Datasheet |
Axial Cylinder, 3 Lead (Radial Bend) | TRIGARD® 2026 | Bulk | Active | 470 V | 20000A (20kA) | ±20% | 3 | Yes | Through Hole |
|
|
2026-47-C2FLFGDT 470V 20KA 3 POLE TH |
7,977 | - |
|
Datasheet |
Axial Cylinder, 3 Lead (Radial Bend) | TRIGARD® 2026 | Bulk | Active | 470 V | 20000A (20kA) | ±20% | 3 | Yes | Through Hole |
|
|
2026-60-C2FLFGDT 600V 20KA 3 POLE TH |
2,932 | - |
|
Datasheet |
Axial Cylinder, 3 Lead (Radial Bend) | TRIGARD® 2026 | Bulk | Active | 600 V | 20000A (20kA) | ±20% | 3 | Yes | Through Hole |