Available 24/7 at
0755-82798135Gas Discharge Tube Arresters (GDT)
Gas Discharge Tube Arresters (GDT)
Gas Discharge Tube Arresters (GDT) are circuit protection components used to protect electronic systems from high-energy surge events, lightning-induced transients and overvoltage conditions. They are widely used in communication equipment, power supplies, industrial control systems, telecom lines, networking devices, security systems, renewable energy equipment, meters and building electrical protection.
This category includes gas discharge tubes, GDT surge arresters, two-electrode GDTs, three-electrode GDTs, lightning protection arresters and related overvoltage protection components. These devices are commonly selected based on DC spark-over voltage, impulse discharge current, insulation resistance, capacitance, response characteristics, package type, safety standards and application requirements.
TomatoElec supplies original Gas Discharge Tube Arresters from recognized manufacturers such as Bourns, Littelfuse, TDK, EPCOS, Vishay, Eaton, Bel Fuse, Murata, Panasonic and other major brands. As an in-stock electronic components supplier and independent distributor, TomatoElec provides inventory support, original component sourcing and BOM sourcing services for global customers.
| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Package/Case | Series | Packaging | Product Status | Voltage - DC Spark Over (Nom) | Impulse Discharge Current (8/20µs) | Tolerance | Number of Poles | Fail Short | Mounting Type |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
2037-30-B5GDT 300V 5KA 2 POLE THROUGH HOLE |
6,763 | - |
|
Datasheet |
Axial Cylinder, Radial Bend | 2037 | Bulk | Active | 300 V | 5000A (5kA) | ±15% | 2 | No | Through Hole |
|
|
2037-42-B5LFGDT 420V 5KA 2 POLE THROUGH HOLE |
6,727 | - |
|
Datasheet |
Axial Cylinder, Radial Bend | 2037 | Bulk | Active | 420 V | 5000A (5kA) | ±15% | 2 | No | Through Hole |
|
|
2037-60-B5GDT 600V 5KA 2 POLE THROUGH HOLE |
3,345 | - |
|
Datasheet |
Axial Cylinder, Radial Bend | 2037 | Bulk | Active | 600 V | 5000A (5kA) | ±15% | 2 | No | Through Hole |
|
|
B88069X0900T103GDT 230V 2.5KA 2 POLE TH |
2,547 | - |
|
Datasheet |
Axial Cylinder | EM | Tape & Reel (TR) | Obsolete | 230 V | 2500A (2.5kA) | ±20% | 2 | No | Through Hole |
|
|
2037-25-B5LFGDT 250V 5KA 2 POLE THROUGH HOLE |
8,702 | - |
|
Datasheet |
Axial Cylinder, Radial Bend | 2037 | Bulk | Active | 250 V | 5000A (5kA) | ±15% | 2 | No | Through Hole |
|
2037-09-B5LFGDT 90V 5KA 2 POLE THROUGH HOLE |
9,866 | - |
|
Datasheet |
Axial Cylinder, Radial Bend | 2037 | Bulk | Active | 90 V | 5000A (5kA) | ±15% | 2 | No | Through Hole |
|
|
GTCN38-231M-Q10GDT 230V 10KA 3 POLE |
5,227 | - |
|
Datasheet |
Cylinder No Lead, 3 Terminal | GT | Bag | Obsolete | 230 V | 10000A (10kA) | ±20% | 3 | No | User Defined |
|
|
GTCN38-900M-Q10GDT 90V 10KA 3 POLE |
2,535 | - |
|
Datasheet |
Cylinder No Lead, 3 Terminal | GT | Bag | Obsolete | 90 V | 10000A (10kA) | ±20% | 3 | No | User Defined |
|
|
2037-15-BGDT 150V 5KA 2 POLE THROUGH HOLE |
2,997 | - |
|
Datasheet |
Axial Cylinder | 2037 | Bulk | Active | 150 V | 5000A (5kA) | ±15% | 2 | No | Through Hole |
|
B88069X1780S102GDT 270V 2.5KA 2 POLE TH |
5,381 | - |
|
Datasheet |
Axial Cylinder | EM | Strip | Active | 270 V | 2500A (2.5kA) | - | 2 | No | Through Hole |
|
|
B88069X5411S102GDT 900V 2KA 2 POLE THROUGH HOLE |
7,915 | - |
|
Datasheet |
Axial Cylinder | EM | Strip | Active | 900 V | 2000A (2kA) | ±20% | 2 | No | Through Hole |
|
B88069X5921S102GDT 150V 2.5KA 2 POLE TH |
5,433 | - |
|
Datasheet |
Axial Cylinder | EM | Strip | Active | 150 V | 2500A (2.5kA) | ±20% | 2 | No | Through Hole |
|
B88069X2810T502GDT 500V 2.5KA 2 POLE TH |
9,420 | - |
|
- |
Axial Cylinder | EM | Tape & Reel (TR) | Active | 500 V | 2500A (2.5kA) | ±20% | 2 | No | Through Hole |
|
B88069X5411T502GDT 900V 2KA 2 POLE THROUGH HOLE |
4,800 | - |
|
Datasheet |
Axial Cylinder | EM | Tape & Reel (TR) | Active | 900 V | 2000A (2kA) | ±20% | 2 | No | Through Hole |
|
|
B88069X6191T103GDT 600V 5KA 2 POLE THROUGH HOLE |
9,743 | - |
|
Datasheet |
Axial Cylinder | M50 | Tape & Reel (TR) | Active | 600 V | 5000A (5kA) | ±20% | 2 | No | Through Hole |
|
B88069X2593T502GDT 600V 2.5KA 2 POLE TH |
8,313 | - |
|
Datasheet |
Axial Cylinder | EM | Tape & Reel (TR) | Active | 600 V | 2500A (2.5kA) | ±20% | 2 | No | Through Hole |
|
2RH3500L-8/TRGDT 3.5KV 2.5KA 2 POLE TH |
2,335 | - |
|
Datasheet |
Axial Cylinder | 2R-8x8 | Tape & Reel (TR) | Active | 3.5 kV | 2500A (2.5kA) | ±20% | 2 | No | Through Hole |
|
2RH3000L-8/TRGDT 3000V 2.5KA 2 POLE TH |
8,739 | - |
|
Datasheet |
Axial Cylinder | 2R-8x8 | Tape & Reel (TR) | Active | 3000 V | 2500A (2.5kA) | ±20% | 2 | No | Through Hole |
|
2RH1400L-8/TRGDT 1400V 2.5KA 2 POLE TH |
2,691 | - |
|
Datasheet |
Axial Cylinder | 2R-8x8 | Tape & Reel (TR) | Active | 1400 V | 2500A (2.5kA) | ±20% | 2 | No | Through Hole |
|
2RH2500L-8/TRGDT 2500V 2.5KA 2 POLE TH |
9,238 | - |
|
Datasheet |
Axial Cylinder | 2R-8x8 | Tape & Reel (TR) | Active | 2500 V | 2500A (2.5kA) | ±20% | 2 | No | Through Hole |