Available 24/7 at
0755-82798135Electrical, Specialty Fuses
Electrical, Specialty Fuses
Electrical and Specialty Fuses are circuit protection components designed to interrupt current during overload, short-circuit or fault conditions in electrical and electronic systems. They are widely used in industrial equipment, power distribution, motor drives, renewable energy systems, communication equipment, automation systems, transportation electronics, power supplies and control panels.
This category includes industrial fuses, specialty fuses, power fuses, cartridge fuses, high-voltage fuses, fast-acting fuses, time-delay fuses, semiconductor protection fuses and related overcurrent protection devices. These components are commonly selected based on current rating, voltage rating, breaking capacity, response speed, fuse size, mounting method, safety approvals and application requirements.
TomatoElec supplies original Electrical and Specialty Fuses from recognized manufacturers such as Littelfuse, Eaton, Bel Fuse, Schurter, Mersen, SIBA, Bourns, TE Connectivity and other major brands. As an in-stock electronic components supplier and independent distributor, TomatoElec provides inventory support, original component sourcing and BOM sourcing services for global customers.
| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Package / Case | Packaging | Product Status | Mounting Type | Fuse Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Response Time | Applications | Features | Class | Approval Agency | Operating Temperature | Breaking Capacity @ Rated Voltage | Size / Dimension | Grade | Qualification |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
|
ANL-400FUSE STRIP 400A 80VDC RECT |
1 | - |
|
Datasheet |
ANL | Rectangular, Blade | Bulk | Active | Bolt Mount | Fuse Strip | 400A | - | 80 VDC | Fast Blow | Lift Trucks | Indicating | - | UR | - | 2.7kA | 0.874" Dia x 3.189" L (22.20mm x 81.00mm) | - | - |
|
|
L50S200.VFUSE CRTRDGE 200A 500VAC/450VDC |
2,290 | - |
|
Datasheet |
POWR-GARD® L50S | Cylindrical, Blade Terminal (Bolt) | Box | Active | Bolt Mount | Cartridge | 200A | 500 VAC | 450 VDC | Fast Blow | Semiconductors | - | - | CE, CSA, UR | - | 200kA AC, 20kA DC | 1.220" Dia x 2.126" L (31.00mm x 54.00mm) | - | - |
|
170M1368FUSE SQUARE 125A 700VAC RECT |
4,246 | - |
|
Datasheet |
- | Rectangular, Blade | Bulk | Active | Bolt Mount | Square | 125A | 700 VAC | - | - | Electrical, Industrial | Indicating | - | CE, UR | - | 200kA | 2.126" L x 0.827" W x 1.575" H (54.00mm x 21.00mm x 40.00mm) | - | - |
|
0AKHBK500-BAFUSE 500A 1000V STUD MNT |
4,361 | - |
|
Datasheet |
0AKH | Rectangular, Blade | Box | Active | Bolt Mount | Square | 500A | - | 1 kVDC | Fast Blow | Electrical, Industrial | - | aR | - | - | 50kA | 2.827" L x 1.850" W x 1.890" H (71.80mm x 47.00mm x 48.00mm) | - | - |
|
L70QS070.VFUSE CARTRIDGE 70A 700VAC/700VDC |
1 | - |
|
Datasheet |
POWR-SPEED™ L70QS | Cylindrical, Blade Terminal (Bolt) | Box | Active | Bolt Mount | Cartridge | 70A | 700 VAC | 700 VDC | Fast Blow | Semiconductors | - | - | CE, cURus, UR | -55°C ~ 125°C | 200kA AC, 50kA DC | 1.000" Dia x 4.375" L (25.40mm x 111.13mm) | - | - |
|
L70QS080.VFUSE CARTRIDGE 80A 700VAC/VDC |
7,068 | - |
|
Datasheet |
POWR-SPEED™ L70QS | Cylindrical, Blade Terminal (Bolt) | Bulk | Active | Bolt Mount | Cartridge | 80A | 700 VAC | 700 VDC | Fast Blow | Semiconductors | - | - | CE, cURus | -55°C ~ 125°C | 200kA AC, 50kA DC | 1.000" Dia x 2.875" L (25.40mm x 73.03mm) | - | - |
|
L70QS100.VFUSE CRTRDGE 100A 700VAC/700VDC |
4,258 | - |
|
Datasheet |
POWR-SPEED™ L70QS | Cylindrical, Blade Terminal (Bolt) | Box | Active | Bolt Mount | Cartridge | 100A | 700 VAC | 700 VDC | Fast Blow | Semiconductors | - | - | CE, cURus, UR | -55°C ~ 125°C | 200kA AC, 50kA DC | 1.000" Dia x 4.375" L (25.40mm x 111.13mm) | - | - |
|
0JTD090.VFUSE CARTRIDGE 90A 600VAC/300VDC |
6,086 | - |
|
Datasheet |
POWR-GARD®, POWR-PRO® JTD | Cylindrical, Blade Terminals | Bulk | Active | Requires Holder | Cartridge | 90A | 600 VAC | 300 VDC | Slow Blow | Transformer Protection | - | J | CE, CSA, UL | - | 200kA AC, 20kA DC | 1.126" Dia x 2.626" L (28.60mm x 66.70mm) | - | - |
|
L50QS225.VFUSE CRTRDGE 225A 500VAC/VDC |
1 | - |
|
Datasheet |
POWR-SPEED™ L50QS | Cylindrical, Blade Terminal (Bolt) | Box | Active | Bolt Mount | Cartridge | 225A | 500 VAC | 500 VDC | Fast Blow | Semiconductors | - | - | CE, cURus, UR | -55°C ~ 125°C | 200kA AC, 50kA DC | 1.500" Dia x 4.343" L (38.10mm x 110.31mm) | - | - |
|
L50QS250.VFUSE CRTRDGE 250A 500VAC/VDC |
1 | - |
|
Datasheet |
POWR-SPEED™ L50QS | Cylindrical, Blade Terminal (Bolt) | Box | Active | Bolt Mount | Cartridge | 250A | 500 VAC | 500 VDC | Fast Blow | Semiconductors | - | - | CE, cURus, UR | -55°C ~ 125°C | 200kA AC, 50kA DC | 1.500" Dia x 4.343" L (38.10mm x 110.31mm) | - | - |
|
L50QS275.VFUSE CRTRDGE 275A 500VAC/VDC |
1 | - |
|
Datasheet |
POWR-SPEED™ L50QS | Cylindrical, Blade Terminal (Bolt) | Box | Active | Bolt Mount | Cartridge | 275A | 500 VAC | 500 VDC | Fast Blow | Semiconductors | - | - | CE, cURus, UR | -55°C ~ 125°C | 200kA AC, 50kA DC | 1.500" Dia x 4.343" L (38.10mm x 110.31mm) | - | - |
|
L25S600.VFUSE CRTRDGE 600A 250VAC/200VDC |
7,658 | - |
|
Datasheet |
POWR-GARD® L25S | Cylindrical, Blade Terminal (Bolt) | Box | Active | Bolt Mount | Cartridge | 600A | 250 VAC | 200 VDC | Fast Blow | Semiconductors | - | - | CE, CSA, UR | - | 200kA AC, 20kA DC | 1.500" Dia x 1.594" L (38.10mm x 40.50mm) | - | - |
|
|
L50S400.VFUSE CRTRDGE 400A 500VAC/450VDC |
2,033 | - |
|
Datasheet |
POWR-GARD® L50S | Cylindrical, Blade Terminal (Bolt) | Box | Active | Bolt Mount | Cartridge | 400A | 500 VAC | 450 VDC | Fast Blow | Semiconductors | - | - | CE, CSA, UR | - | 200kA AC, 20kA DC | 1.500" Dia x 2.094" L (38.10mm x 53.20mm) | - | - |
|
FWH-100AFUSE CARTRIDGE 100A 500VAC/VDC |
1 | - |
|
Datasheet |
FWH | Cylindrical, Blade Terminal (Bolt) | Bulk | Active | Bolt Mount | Cartridge | 100A | 500 VAC | 500 VDC | - | Electrical, Industrial | - | - | CE, CSA, UR | - | 200kA AC, 50kA DC | - | - | - |
|
L17T800.VFUSE CRTRDGE 800A 170VDC CYLINDR |
1 | - |
|
Datasheet |
POWR-GARD® L17T | Cylindrical, Blade Terminal (Bolt) | Box | Active | Bolt Mount | Cartridge | 800A | - | 170 VDC | Fast Blow | Telecom | - | - | CE, CSA, UR | - | 100kA | 1.500" Dia x 1.252" L (38.10mm x 31.80mm) | - | - |
|
FLSR125.XXIDFUSE CRTRDGE 125A 600VAC/300VDC |
1 | - |
|
Datasheet |
POWR-GARD® FLSR_ID | Cylindrical, Blade Terminals | Box | Active | Requires Holder | Cartridge | 125A | 600 VAC | 300 VDC | Slow Blow | Electrical, Industrial | Indicating | RK5 | CE, CSA, QPL, UL | - | 200kA AC, 20kA DC | 1.843" Dia x 9.626" L (46.80mm x 244.50mm) | - | - |
|
L70QS175.VFUSE CRTRDGE 175A 700VAC/700VDC |
1 | - |
|
Datasheet |
POWR-SPEED™ L70QS | Cylindrical, Blade Terminal (Bolt) | Box | Active | Bolt Mount | Cartridge | 175A | 700 VAC | 700 VDC | Fast Blow | Semiconductors | - | - | CE, cURus, UR | -55°C ~ 125°C | 200kA AC, 50kA DC | 1.218" Dia x 5.085" L (30.94mm x 129.16mm) | - | - |
|
L70QS200.VFUSE CRTRDGE 200A 700VAC/700VDC |
1 | - |
|
Datasheet |
POWR-SPEED™ L70QS | Cylindrical, Blade Terminal (Bolt) | Box | Active | Bolt Mount | Cartridge | 200A | 700 VAC | 700 VDC | Fast Blow | Semiconductors | - | - | CE, cURus, UR | -55°C ~ 125°C | 200kA AC, 50kA DC | 1.218" Dia x 5.085" L (30.94mm x 129.16mm) | - | - |
|
|
JLLN600.XFUSE CRTRDGE 600A 300VAC/125VDC |
1 | - |
|
Datasheet |
POWR-GARD® JLLN | Cylindrical, Blade Terminal (Bolt) | Box | Active | Bolt Mount | Cartridge | 600A | 300 VAC | 125 VDC | Fast Blow | Electrical, Industrial | - | T | CE, CSA, UL | - | 200kA AC, 20kA DC | 1.594" Dia x 0.874" L (40.50mm x 22.20mm) | - | - |
|
L70S150.VFUSE CRTRDGE 150A 700VAC/650VDC |
1 | - |
|
Datasheet |
POWR-GARD® L70S | Cylindrical, Blade Terminal (Bolt) | Box | Active | Bolt Mount | Cartridge | 150A | 700 VAC | 650 VDC | Fast Blow | Semiconductors | - | - | CE, CSA, UR | - | 200kA AC, 20kA DC | 1.500" Dia x 2.843" L (38.10mm x 72.20mm) | - | - |