Available 24/7 at
0755-82798135Circuit Breakers
Circuit Breakers
Circuit Breakers are circuit protection devices used to interrupt current during overcurrent, short-circuit or fault conditions. Unlike one-time fuses, many circuit breakers can be reset after the fault is cleared, making them suitable for systems that require repeatable protection, maintenance convenience and reliable electrical safety.
This category includes thermal circuit breakers, magnetic circuit breakers, thermal-magnetic circuit breakers, resettable circuit breakers, panel mount circuit breakers and related overcurrent protection devices. These components are commonly selected based on current rating, voltage rating, trip characteristics, breaking capacity, reset type, mounting method, package style, safety approvals and application requirements.
TomatoElec supplies original Circuit Breakers from recognized manufacturers such as Littelfuse, Eaton, TE Connectivity, Schurter, Phoenix Contact, Schneider Electric, Siemens, Sensata and other major brands. As an in-stock electronic components supplier and independent distributor, TomatoElec provides inventory support, original component sourcing and BOM sourcing services for global customers.
| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Packaging | Product Status | Mounting Type | Breaker Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Actuator Type | Number of Poles | Illumination | Illumination Voltage (Nominal) | Approval Agency |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
NDB3100Z420-1LSS1A0LUL489A Listed, these panel or ra |
6 | - |
|
- |
- | Retail Package | Active | - | - | - | - | - | - | - | - | - | - |
|
LELK1-1REC4R-37086-30CIR BRKR MAG-HYDR LEVER |
31 | - |
|
Datasheet |
LEL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | - | - | - | Lever | 1 | - | - | - |
|
QZ113D930QZ113D930 is a 30 amp space savi |
6 | - |
|
- |
QZ | Retail Package | Active | DIN Rail | Magnetic (Hydraulic Delay) | 30A | 240 V | - | Lever | 1 | None | - | UL1077 |
|
104-P10-2ACIR BRKR THRM 2A 250VAC 48VDC |
37 | - |
|
Datasheet |
104 | Bulk | Active | Panel Mount | Thermal | 2A | 240 V | 48 V | Push to Reset | 1 | - | - | CE, CSA C22.2 No 235, GB 17701, IEC 60934, UL1077 |
|
4435.0146CIR BRKR THRM 240VAC ROCKER |
20 | - |
|
Datasheet |
TA35 | Bulk | Obsolete | Panel Mount | Thermal | - | 240 V | - | Rocker | 3 | - | - | - |
|
1278860000CIR BRKR THRM 250MA 250VAC 65VDC |
9 | - |
|
Datasheet |
1180 | Bulk | Active | Holder | Thermal | 250mA | 250 V | 72 V | Push-Push | 1 | - | - | CSA C22.2 No 235, UL1077, VDE |
|
|
1278850000CIR BRKR THRM 200MA 250VAC 65VDC |
15 | - |
|
Datasheet |
1180 | Bulk | Active | Holder | Thermal | 200mA | 250 V | 72 V | Push-Push | 1 | - | - | CSA C22.2 No 235, UL1077, VDE |
|
MX36-GCA-120CIR BRKR 120A 48VDC PUSH-RESET |
40 | - |
|
Datasheet |
MX36-GCA | Bulk | Active | Panel Mount | - | 120A | - | 48 V | Push to Reset | 1 | None | - | cUL, UL |
|
4435.0086CIR BRKR THRM 10A 240VAC 60VDC |
19 | - |
|
Datasheet |
TA35 | Bulk | Obsolete | Panel Mount | Thermal | 10A | 240 V | 60 V | Rotary | 2 | - | - | - |
|
4435.0346CIR BRKR THRM 17A 240VAC 60VDC |
18 | - |
|
Datasheet |
TA35 | Bulk | Obsolete | Panel Mount | Thermal | 17A | 240 V | 60 V | Rotary | 2 | - | - | - |
|
2480490000MCB 1077 3P C 1.2A ACDC |
16 | - |
|
- |
- | Bulk | Active | - | Thermal Magnetic | 1.2A | - | - | - | 3 | - | - | - |
|
2479920000MCB 1077 3P B 20A ACDC |
15 | - |
|
- |
- | Bulk | Active | - | Thermal Magnetic | 20A | - | - | - | 3 | - | - | - |
|
2479870000MCB 1077 3P B 10A ACDC |
11 | - |
|
- |
- | Bulk | Active | - | Thermal Magnetic | 10A | - | - | - | 3 | - | - | - |
|
|
R11-4-5.00A-R01CV-VCIR BRKR MAGHYDR 5A 250VAC 65VDC |
30 | - |
|
Datasheet |
SNAPAK® | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 5A | 250 V | 65 V | Rocker | 1 | - | - | - |
|
PP11-62F-20.0A-37197-6CIR BRKR MAG-HYDR PUSH-PULL |
25 | - |
|
Datasheet |
SNAPAK® | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | - | - | - | Push-Pull Plunger | 1 | - | - | - |
|
NDB2-63C63-2DIN rail mount circuit breaker, |
35 | - |
|
Datasheet |
NDB2 | Tape & Box (TB) | Active | DIN Rail | Thermal Magnetic | 63A | 480 V | 125 V | Lever | 2 | None | - | CCC, TUV, UL1077 |
|
4435.0023CIR BRKR THRM 2.8A 240VAC 60VDC |
10 | - |
|
Datasheet |
TA35 | Bulk | Active | Panel Mount | Thermal | 2.8A | 240 V | 60 V | Rocker | 2 | - | - | - |
|
NC1V-1100-3AACIRCUIT PROTECTOR 1 POLE 3A |
19 | - |
|
Datasheet |
NC1V | Bulk | Obsolete | DIN Rail | Magnetic (Hydraulic Delay) | 3A | 250 V | 65 V | Lever | 1 | None | - | UL1077 |
|
R15-62-10.0A-40026-10-VCIR BRKR MAG-HYDR 10A ROCKER |
6,749 | - |
|
Datasheet |
SNAPAK® | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 10A | - | - | Rocker | 1 | - | - | - |
|
1100-CB1C2U10UL 489, 1 POLE, 10A TRIP CURVE C |
99 | - |
|
- |
1100 | Box | Active | DIN Rail | Thermal Magnetic | 10A | 277 V | 48 V | Lever | 1 | None | - | CE, CSA C22.2 No. 5, cULus, UL489 |