Available 24/7 at
0755-82798135Circuit Breakers
Circuit Breakers
Circuit Breakers are circuit protection devices used to interrupt current during overcurrent, short-circuit or fault conditions. Unlike one-time fuses, many circuit breakers can be reset after the fault is cleared, making them suitable for systems that require repeatable protection, maintenance convenience and reliable electrical safety.
This category includes thermal circuit breakers, magnetic circuit breakers, thermal-magnetic circuit breakers, resettable circuit breakers, panel mount circuit breakers and related overcurrent protection devices. These components are commonly selected based on current rating, voltage rating, trip characteristics, breaking capacity, reset type, mounting method, package style, safety approvals and application requirements.
TomatoElec supplies original Circuit Breakers from recognized manufacturers such as Littelfuse, Eaton, TE Connectivity, Schurter, Phoenix Contact, Schneider Electric, Siemens, Sensata and other major brands. As an in-stock electronic components supplier and independent distributor, TomatoElec provides inventory support, original component sourcing and BOM sourcing services for global customers.
| Photo | Mfr. Part # | Availability | Price | Quantity | Datasheet | Series | Packaging | Product Status | Mounting Type | Breaker Type | Current Rating (Amps) | Voltage Rating - AC | Voltage Rating - DC | Actuator Type | Number of Poles | Illumination | Illumination Voltage (Nominal) | Approval Agency |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
|
C10A3PCIR BRKR MAG-HYDR 10A 480VAC |
19 | - |
|
Datasheet |
- | Tray | Active | DIN Rail | Magnetic (Hydraulic Delay) | 10A | 480 V | - | Lever | 3 | - | - | CE, UL1077, UR |
|
C40A3PCIR BRKR MAG-HYDR 40A 480VAC |
8 | - |
|
Datasheet |
- | Tray | Active | DIN Rail | Magnetic (Hydraulic Delay) | 40A | 480 V | - | Lever | 3 | - | - | CE, UL1077, UR |
|
C30A3PCIR BRKR MAG-HYDR 30A 480VAC |
4 | - |
|
Datasheet |
- | Box | Active | DIN Rail | Magnetic (Hydraulic Delay) | 30A | 480 V | - | Lever | 3 | - | - | CE, UL1077, UR |
|
4130-G411-K4M1-50ACIR BRKR THRM 50A 240VAC 50VDC |
21 | - |
|
Datasheet |
4130 | Bulk | Active | Panel Mount | Thermal | 50A | 240 V | 50 V | Push to Reset | 1 | None | - | CSA C22.2 No 235, IEC 60934, UL1077 |
|
209-1-1-53-2-9-100CIR BRKR MAG-HYDR 100A 125VDC |
3 | - |
|
Datasheet |
209 | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 100A | - | 125 V | Lever | 1 | - | - | - |
|
209-1-1-51-2-9-100CIR BRKR MAG-HYDR 100A 125VDC |
3 | - |
|
Datasheet |
209 | Bulk | Active | DIN Rail | Magnetic (Hydraulic Delay) | 100A | - | 125 V | Lever | 1 | - | - | - |
|
|
IEGH11-1-72-20.0-91-VCIR BRKR 20A 250VAC 80VDC |
11 | - |
|
Datasheet |
IEG | Tray | Active | Panel Mount | Magnetic (Hydraulic Delay) | 20A | 250 V | 80 V | Lever | 2 | None | - | CSA, TUV, UL1077 |
|
IEG11-1-62-15.0-01-VCIR BRKR MAG-HYDR LEVER 15A |
3 | - |
|
Datasheet |
IEG | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 15A | - | - | Lever | 2 | - | - | CSA, TUV, UL1077 |
|
HCB-2/25/Q120/240V 25A 2P CIRCUIT BREAKER, |
22 | - |
|
Datasheet |
HCB | Box | Active | DIN Rail | Thermal Magnetic | 25A | 240 V | - | Lever | 2 | None | - | CSA C22.2 No 5-02, UL489 |
|
LELK1-1RS4-30452-30CIR BRKR MAG-HYDR LEVER |
15 | - |
|
Datasheet |
LEL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 30A | - | 80 V | Lever | 1 | - | - | UL489 |
|
LELK1-1REC4-30326-60CIR BRKR MAG-HYDR LEVER |
25 | - |
|
Datasheet |
LEL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 60A | - | 80 V | Lever | 1 | - | - | UL489 |
|
LELK1-1REC4-30326-40CIR BRKR MAG-HYDR LEVER |
5 | - |
|
Datasheet |
LEL | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | - | - | - | Lever | 1 | - | - | - |
|
2478510000CB MCB 489 3P C 50A ACDC |
4 | - |
|
Datasheet |
MCB 489 | Bulk | Active | DIN Rail | Thermal Magnetic | 50A | 240 V | - | Lever | 3 | None | - | CE, CSA C22.2 No 5, CSA C22.2 No 235, TUV, UL489, VDE |
|
IEG11-1-63F-15.0-01-VCIR BRKR MAG-HYDR LEVER 15A |
14 | - |
|
Datasheet |
IEG | Bulk | Active | Panel Mount | Magnetic (Hydraulic Delay) | 15A | - | - | Lever | 2 | - | - | CSA, TUV, UL1077 |
|
7940102677QY-2-13-DM-U2-05-B1 125 VDC |
10 | - |
|
- |
QY | Bulk | Active | DIN Rail | Magnetic (Hydraulic Delay) | 5A | 240 V | 125 V | Lever | 2 | None | - | CE, CSA C22.2 No 235, UL1077, VDE |
|
787-2861/200-000ELECTRONIC CIRCUIT BREAKER; 1-CH |
24 | - |
|
Datasheet |
- | Bag | Active | DIN Rail | - | 2A | - | 24 V | Not Included | 1 | None | - | CE, DNV GL, EAC, UL |
|
787-2861/400-000ELECTRONIC CIRCUIT BREAKER; 1-CH |
2 | - |
|
Datasheet |
- | Bag | Active | DIN Rail | - | 4A | - | 24 V | Not Included | 1 | None | - | CE, DNV GL, EAC, UL |
|
413-K14-LN2-35ACIR BRKR THRM 35A 115VAC 28VDC |
7 | - |
|
Datasheet |
413 | Bulk | Active | Panel Mount | Thermal | 35A | 115 V | 28 V | Push-Pull Plunger | 1 | None | - | CSA C22.2 No 235, UL1077 |
|
3D40UMCIR BRKR THRM-MAG 40A LEVER |
4 | - |
|
Datasheet |
V-EA | Bulk | Active | DIN Rail | Thermal Magnetic | 40A | 480 V | - | Lever | 3 | None | - | CSA, UL508 |
|
4230-T130-K0CU-35ACIR BRKR THERM 35A 480VAC/125VDC |
2 | - |
|
Datasheet |
4230-T | Bulk | Active | DIN Rail | Thermal Magnetic | 35A | 480 V | 125 V | Lever | 3 | None | - | CSA C22.2 No 235, UL489 |